Posted in

How to adjust the flow rate of a three screw pump?

If you’ve ever worked with industrial fluid transfer systems, you know that a three screw pump is one of the most reliable workhorses for moving lubricants, hydraulic oils, fuels, and even viscous chemicals. But here’s the thing: even the best three screw pump won’t perform up to its potential if your flow rate is off. As a supplier who’s spent years troubleshooting, installing, and fine-tuning these pumps for clients across manufacturing, mining, and marine industries, I’ve seen firsthand how an incorrect flow rate can throw off production, waste energy, and even cause premature pump wear. Today, I’m walking you through exactly how to adjust your three screw pump’s flow rate—step by step, with the kind of practical insight only someone who sells and supports these pumps can offer. Three Screw Pump

First, let’s get one basic fact straight: unlike some positive displacement pumps that rely on variable speed drives alone, a three screw pump’s flow rate is a product of its design (size, screw pitch, and speed) and how you operate it. The core function of a three screw pump is simple: a central power screw meshes with two idler screws, creating sealed chambers that move fluid from inlet to outlet. Adjusting flow rate without damaging this precision-engineered set of screws is all about working with that design, not against it.

Before you even touch any adjustment parts, you need to know two key things about your specific pump: its rated flow rate (the number printed on your pump’s nameplate, matched to your operating speed) and the minimum/maximum flow limits recommended by the manufacturer. This isn’t just red tape—running a three screw pump below 20% of its rated flow for extended periods can cause overheating, because the trapped fluid in the pump’s casings doesn’t circulate to carry away heat. Going above 110% of rated flow can strain the motor and wear out the screws faster. I always tell new clients: if you’re adjusting flow to hit a target that falls outside those limits, you’re better off talking to a pump specialist before making changes.

Now, the most common method for adjusting flow rate on a standard three screw pump is changing its rotational speed. This is the safest, most cost-effective way, and it’s the method I recommend 9 times out of 10. The relationship between speed and flow rate is linear here: if you double the RPM of the pump, you double the flow rate (assuming viscosity and pressure stay consistent). That’s a straightforward rule, but let’s break down how to do it properly.

If your pump is connected to a fixed-speed motor, you’ll need to install a variable frequency drive (VFD) to adjust speed. Wait, I know what some of you are thinking: “VFDs are expensive for small adjustments.” But here’s the reality— a VFD pays for itself in a matter of months by eliminating wasted energy and preventing pump damage. I’ve had clients who tried to get by with throttling the discharge valve instead of using a VFD, and they burned out three screw pumps in 18 months because throttling creates excess back pressure that forces fluid to recirculate inside the pump. Throttling is a no-no for three screw pumps, full stop. If you need to adjust flow, skip the valve and adjust the motor speed instead.

To adjust speed with a VFD: first, make sure you match the VFD’s horsepower and voltage to your pump’s motor—using an incompatible VFD can cause voltage spikes that damage the motor windings. Next, start with small speed increments: aim to adjust by no more than 10% of your pump’s rated RPM at a time. After each adjustment, run the pump for 5 to 10 minutes at operating pressure, then measure the actual flow rate with a calibrated flow meter (don’t rely on your system’s gauge alone—those are often off by 5% or more). If your flow is still too high, lower the RPM slightly; if it’s too low, increase it. Keep an eye on the pump’s discharge pressure throughout this process—most three screw pumps operate best at 10 to 15 bar, but check your nameplate for the exact range. If pressure spikes, slow the speed down; if pressure drops, you can nudge it up a bit.

There are cases where changing speed isn’t an option—for example, if your pump is hardwired to a fixed-speed motor in a critical, uninterruptable process. In that scenario, you can adjust flow rate by changing the pump’s screw set or the internal bypass valve— but this is a more advanced adjustment, and I always advise clients to consult a qualified technician (and their pump supplier) before attempting it. Let me explain how that bypass method works, because it’s a common fix for fixed-speed applications. Most three screw pumps have a built-in bypass line that diverts excess fluid from the discharge side back to the inlet, effectively reducing the net flow to your system. The bypass valve is usually located on the pump’s casing, often near the outlet flange. To adjust it, you’ll loosen the lock nut on the valve, then turn the adjustment screw clockwise to close the valve (reducing flow) or counterclockwise to open it (increasing flow). But here’s the catch: when you open the bypass, you’re sending a portion of the pump’s output back to the inlet, which means the pump is still working as hard as it would at full flow. That wastes energy and generates extra heat. I only recommend this as a temporary solution, or for applications where flow adjustments are minimal. If you’re relying on the bypass for more than 20% of your flow reduction, you’re better off upgrading to a variable speed drive long-term.

Another less common adjustment is changing the pump’s screw pitch. Three screw pumps are manufactured with different screw pitches to achieve different flow rates at the same speed. If you need a permanent flow rate change—say, your production line output increased by 30% and your current pump can’t keep up—swapping out the screw set is the way to go. But this isn’t a DIY job. The central power screw and two idler screws are machined to extremely tight tolerances (often within microns), so even a small mistake during installation can cause internal leaks or screw damage. Last year, a client tried to swap screws on their own, and they ended up with a flow rate 15% lower than target, plus noise and vibration that cost them a new pump. If you’re thinking of changing screw pitch, reach out to your pump supplier—we can provide pre-machined screw sets and guide you through installation, or send a technician to do it for you.

No matter which adjustment method you choose, there are a few critical safety checks you need to do before and after making any changes. First, lock out and tag out the pump’s power source before you start working on it—this is non-negotiable, even if you think the pump is turned off. Next, check the pump’s fluid level: three screw pumps rely on the lubricating properties of the fluid they’re moving to cool and lubricate the screws. If the fluid is too low, running the pump during adjustment will cause friction and overheating. After you make your adjustment, run the pump at low speed for a minute, then listen for any unusual noise—grinding or knocking is a sign that the screw alignment is off, and you need to shut it down immediately. Also, check the pump’s temperature: if it’s more than 10°C above the fluid’s temperature, that’s a red flag that you’re either running it outside its flow limit or there’s an internal issue.

I’ve spent thousands of hours on job sites with three screw pumps, and one of the most common mistakes I see is people adjusting flow without understanding the pump’s operating limits. Last quarter, a mine client contacted me because their pump was moving 20% less fluid than needed to feed their processing line. They’d tried to fix it by cranking the bypass valve all the way open, but that caused the pump to overheat and trip the safety switch. By the time they called me, the pump’s bearings were already damaged. We ended up installing a VFD, adjusting the speed, and restoring the flow to target without any further damage, but that experience stuck with me: adjust flow right, and your pump runs reliably for years; adjust it wrong, and you’re looking at costly downtime and repairs.

Now, let’s talk about when to consider other adjustments. If you’ve tried adjusting speed, checking the bypass, and swapping screws (if needed) and your flow rate is still off, the problem might not be the adjustment—it could be something else. Clogged inlet filters, worn out suction lines, or damaged screws from lack of maintenance are all common culprits. I always advise clients to inspect the pump’s inlet filter every 3 months, and replace it if it’s clogged— a blocked filter reduces suction pressure, which can make the pump’s flow rate seem low even if the pump is working correctly. Worn screws are another issue: over time, the meshing surfaces of the central and idler screws wear down, creating internal leaks that reduce flow. If you’ve had your pump for 5 years or more, that might be the cause, and you’ll need a screw replacement or a whole pump upgrade.

At the end of the day, adjusting a three screw pump’s flow rate doesn’t have to be complicated. The key is to stick to the safe methods: start with speed adjustment, avoid throttling valves, and never run the pump outside its rated flow limits. If you’re unsure at any step, don’t guess—reach out to a supplier who knows three screw pumps inside and out. I’ve worked with enough clients to know that the best solution is almost always the one that balances performance, efficiency, and longevity.

If you’re struggling to get your three screw pump’s flow rate where it needs to be, or if you’re considering upgrading to a variable speed setup or replacement screws, we’re here to help. We’ve supported clients across all industries with pump adjustments, maintenance, and custom solutions that fit their specific needs. Just reach out to our team to discuss your pump’s requirements and find the right adjustment for your operation.

Hydraulic Diaphragm Metering Pump References:

  1. Hydraulic Institute. (2019). Rotary Pump Application and Installation Standards.
  2. ISO 13347:2015. Petroleum and liquid petroleum products — Rotary positive displacement pumps — Vocabulary.
  3. European Pump Manufacturers Association (EU Pump). (2021). Best Practices for Three Screw Pump Operation and Maintenance.
  4. Fluid Power Society. (2020). Variable Speed Drive Applications for Industrial Positive Displacement Pumps.

DEPAMU (Hangzhou) Pumps Technology Co., Ltd.

Address: No. 658, 20th Street, Hangzhou Economic & Technological Development Zone, Hangzhou City, Zhejiang Province, China
E-mail: international@depamu.com
WebSite: https://www.depamupumps.com/